Ventricular Assist Devices for Neonates and Infants

      Heart transplant waitlist survival in pediatric patients has been substantially improved since the introduction of pediatric-specific ventricular assist device. In neonates and infants, however, the waitlist mortality remains very high. The only long-term device currently approved for use in the United States is the Berlin Heart EXCOR, but this device has several important limitations because of the paracorporeal, pulsatile nature of the underlying technology. We reviewed Stanford ventricular assist experience on patients less than 1 year old since 2004. It shows overall 1-, 3-, and 5-year survival were 68%, 62%, and 49%, respectively. There are statistically significant differences in survival among cardiomyopathy group, end-stage congenital heart disease group and single ventricle group. In order to improve outcomes in this extremely high risk group, modifications were made to anticoagulation protocols, cannulation strategy in hypertrophic cardiomyopathy patients, and preferential use of continuous flow pumps in a single ventricle patients. The long-waited PumpKIN trial testing the Jarvik 2015 is about to start with the first human implant.
      To read this article in full you will need to make a payment

      References

        • Zafar F.
        • Castleberry C.
        • Khan M.S.
        • et al.
        Pediatric heart transplant waiting list mortality in the era of ventricular assist devices.
        J Heart Lung Transplant. 2015; 34: 82-88
        • Almond C.S.
        • Morales D.L.
        • Blackstone E.H.
        • et al.
        Berlin Heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children.
        Circulation. 2013; 127: 1702-1711
        • Conway J.
        • St Louis J.
        • Morales D.L.
        • et al.
        Delineating survival outcomes in children <10 kg bridged to transplant or recovery with the Berlin Heart EXCOR Ventricular Assist Device.
        JACC Heart Fail. 2015; 3: 70-77
        • Jordan L.C.
        • Ichord R.N.
        • Reinhartz O.
        • et al.
        Neurological complications and outcomes in the Berlin Heart EXCOR® pediatric investigational device exemption trial.
        J Am Heart Assoc. 2015; 4: e001429
        • Miller L.W.
        • Pagani F.D.
        • Russell S.D.
        • et al.
        Use of a continuous-flow device in patients awaiting heart transplantation.
        N Engl J Med. 2007; 357: 885-896
        • Aaronson K.D.
        • Slaughter M.S.
        • Miller L.W.
        • et al.
        Heartware ventricular assist device (HVAD) bridge to transplant ADVANCE trial investigators.
        Circulation. 2012; 125: 3191-3200
        • Luciani G.B.
        • Hoxha S.
        • Torre S.
        • et al.
        Improved outcome of cardiac extracorporeal membrane oxygenation in infants and children using magnetic levitation centrifugal pumps.
        Artif Organs. 2016; 40: 27-33
      1. ROTAFLOW Centrifugal Pump.
        • Mongé M.C.
        • Kulat B.T.
        • Eltayeb O.
        • et al.
        Novel modifications of a ventricular assist device for infants and children.
        Ann Thorac Surg. 2016; 102: 147-153
        • Byrnes J.W.
        • Bhutta A.T.
        • Rettiganti M.R.
        • et al.
        Steroid therapy attenuates acute phase reactant response among children on ventricular assist device support.
        Ann Thorac Surg. 2015; 99: 1392-1398
        • Rosenthal D.N.
        • Lancaster C.A.
        • McElhinney D.B.
        • et al.
        Impact of a modified anti-thrombotic on stroke in children supported with a pediatric ventricular assist device.
        J Heart Lung Transplant. 2017; 36: 1250-1257
        • Lohmann D.P.
        • Swartz M.T.
        • Pennington D.G.
        • et al.
        Left ventricular versus left atrial cannulation for the Thoratec ventricular assist device.
        ASAIO Trans. 1990; 36: M545-M548
        • Hoganson D.
        • Gazit A.
        • Boston U.
        • et al.
        Paracorporeal lung assist device as a bridge to recovery or lung transplantation in neonates and young children.
        J Thorac Cardiovasc Surg. 2014; 147: 420-427
        • Ma M.
        • Yarlagadda V.V.
        • Rosenthal D.N.
        • et al.
        A novel inflow cannulation strategy for pediatric mechanical circulatory support in small left ventricles.
        J Thorac Cardiovasc Surg. 2017; 154 (pii: S0022-5223(17)30537-8): e47-e48
        • Dykes J.C.
        • Reinhartz O.
        • Almond C.S.
        • et al.
        Alternative cannulation strategy for biventricular assist device in an infant with hypertrophic cardiomyopathy.
        Ann Thorac Surg. 2017; 104: e185-e186
        • Lal A.K.
        • Chen S.
        • Maeda K.
        • et al.
        Successful bridge to transplant with a continuous flow ventricular assist device in a single ventricle patient with an aortopulmonary shunt.
        ASAIO J. 2014; 60: 119-121
        • Fujii Y.
        • Ferro G.
        • Kagawa H.
        • et al.
        Is continuous flow superior to pulsatile flow in single ventricle mechanical support? Results from a large animal pilot study.
        ASAIO J. 2015; 61: 443-447
        • Baldwin J.T.
        • Adachi I.
        • Teal J.
        • et al.
        Closing in on the PumpKIN trial of the Jarvik 2015 ventricular assist device.
        Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu. 2017; 20: 9-15